Technical Papers & Research
AI-curated academic research for power system engineers
Grid Operations & Resilience 4 papers
Spatial differences in nodal frequency are amplified through frequency-voltage coupling in inverter-based resources, with existing analyses neglecting voltage dynamics or only examining aggregate frequency. A new unified model captures the device-network F-V coupling, revealing how source configuration and parameters modify the effect of amplifying nodal frequency differences. The model's computational efficiency is validated through case studies on two test systems.
Transversal passivity is a local dissipation property that regulates input and output signals to prescribed manifolds, allowing motion along the manifolds without penalty. It provides a necessary and sufficient condition for the property and relates it to existing passivity notions, and can be assessed before closed-loop analysis. The property has implications for power conservation and port convergence in feedback interconnections through negative-adjoint linear channels.
Conflict-aware impedance-sensitivity-based tuning improves simultaneous damping enhancement of multiple modes, converting impedance-derived eigenvalue sensitivities into normalized damping-ratio sensitivities to diagnose tuning directions. A low-dimensional max--min problem maximizes predicted damping of the worst target mode subject to parameter limits and feasibility requirements. This method has been successfully tested on two test systems, demonstrating the value of pairwise coordination.
Measured voltage and current waveforms can be represented in a reference frame with a different frequency than the physical fundamental frequency, but changing the readout operator can alter reactive-power readouts. A new covariance formulation is presented that ensures consistent transformation of the readout operator with the waveform representation. The formulation provides a necessary condition for determining the consistency of the readout operator and separates errors caused by waveform projections from errors due to measurement uncertainty.
Energy Storage & Markets 1 papers
The article presents a method for coordinating primary and secondary frequency regulation in grid-forming battery energy storage systems using a multi-period bilevel program. The proposed method uses a continuation approach to handle numerical difficulties introduced by complementarity constraints, and it is proven to satisfy a first-order stationarity condition. This approach reduces solution time by 89.3% and peak frequency deviation by 0.53% compared to conventional methods.
Other 5 papers
Training machine learning models to imitate MPC algorithms typically follows a traditional supervised learning flow with either uniformly distributed data or simulation data, but these methods have limitations. A new method combines the benefits of both by using importance weights from kernel density estimation of experimental data to target specific regions of the operating space. This approach results in measurable performance improvements, as demonstrated through the imitation of a moving discretized control set MPC algorithm for a dual active bridge converter.
Phase locking in oscillator networks is highly dependent on interaction strengths between coupled units, particularly when couplings are uncertain, state-dependent, or time varying. Rigorous conditions for phase locking are derived using a convex formulation of nonlinear fixed-point equations, yielding edge-wise error bounds for feasible approximations. These bounds provide sufficient conditions for the existence of phase-locked states with prescribed phase-difference limits.
Researchers used a Monte Carlo simulation to estimate the simultaneous charging factor of electric vehicles in Phu Quoc City, Vietnam, across three scenarios, finding that it decreases as EV penetration increases. The study reported a decline in simultaneous charging factor for electric buses from 0.76 in 2030 to 0.59 in 2040, while other vehicle groups also showed decreasing trends. The findings provide practical insights for grid-aware charging infrastructure planning.
Large data center projects introduce unique transmission planning uncertainty due to their scale, discrete project realization nature, and locational impacts on the transmission network. A new framework is proposed to model, plan, and evaluate transmission expansion under uncertain data center realization, which represents candidate projects through alternative realization scenarios and associated probabilities. This framework demonstrates the effectiveness of stochastic planning and its benefits in providing a balanced tradeoff between transmission investment and reliability exposure.
A closed-loop grid-mode-adaptive hybrid energy storage system control framework is proposed to mitigate AI data center oscillations, integrating measurement-based modal identification with mode-selective control. The framework reduces grid-side modal power component by 76.94% and frequency deviation when the grid mode changes, outperforming a fixed-target controller. The adaptive method achieves this by retuning the modal suppression branch assigned to the supercapacitor based on real-time grid dynamics.