Technical Papers & Research
AI-curated academic research for power system engineers
Grid Operations & Resilience 4 papers
A proposed two-layer framework schedules inference workloads to compensate for rapid power variations caused by synchronous checkpoints in large language model training, reducing maximum absolute frequency deviation by 41.6-61.6% and mean absolute frequency deviation by 68.5-89.6%. The framework also reduces battery energy storage system peak charging power and charging energy by 65.1-100%. Scheduling benefits exceed those of greedy scheduling when GPU resources are relatively abundant.
KPG193-ext, a synthetic Korean power-grid test system, was developed to assess stability analysis across operating conditions. The extension adds detailed electrical and dynamic models, including synchronous machines, controllers, and renewable converters, to the original 193-bus network. The resulting system provides a common basis for examining the stability implications of commitment, dispatch, and corrective action across daily and seasonal operating conditions.
DC voltage control dominated oscillations in the electromechanical frequency range (EFR) are caused by network-mediated interactions among inverter-based resources (IBRs), introducing a negative synchronous coefficient into the DVC oscillation loop. This synchronous coefficient reduction effect (SCRE) becomes stronger with increasing IBR plant scale and/or decreasing network admittance matrix minimum eigenvalue. A complex vector-based stability analysis method is proposed to assess the stability of DVC-EFOs.
MAC+ is a mobility-aware co-expansion planning approach that coordinates electric vehicle charging along itineraries to reduce peak violations and optimize distribution grid and port capacity. The approach, which uses iterated price response, solves a complex optimization problem to minimize costs and optimize charging. By coordinating charging, MAC+ can save up to $15 billion in upgrade investment compared to unmanaged charging, and requires significantly less investment than fully coordinated but flexible or flexible but uncoordinated charging.
Energy Storage & Markets 1 papers
Battery energy storage systems (BESSs) can provide frequency regulation but this service accelerates aging, particularly at extreme state of charge (SoC). By proposing an adaptive bidding strategy and deliberately sacrificing performance to avoid extreme SoC, BESSs can extend battery life by up to 31% and maintain revenue of at most 0.2%. This approach can help mitigate the impact of frequency regulation on battery lifespan.
Renewable Integration 1 papers
A comparative life-cycle assessment of GaN-based current-source and voltage-source AC-AC variable speed drives reveals that the current-source converter (CSC) has a lower life-cycle carbon footprint, particularly under a carbon-intense electricity mix, with a difference of around 900 kgCO2eq compared to the voltage-source converter (VSC). The embodied carbon footprints of both devices are similar. The life-cycle carbon footprint of the CSC is heavily dependent on the electricity mix, with a significant reduction when using a renewable electricity mix.
Other 1 papers
The PJM Interconnection's fossil fleet's carbon intensity is significantly misstated by the locational marginal emission rate (LME), which incorrectly estimates a 1 GW ramp by over 10% in 60-83% of hours. The actual emission caused by a ramp varies by a quarter to three quarters of hours, and location-based reporting assigns 47-59% of the emission to other consumers. A data center should prioritize reporting the emission it causes based on its actual load change.