Technical Papers & Research
AI-curated academic research for power system engineers
Grid Operations & Resilience 6 papers
A grey-box system identification method is proposed for identifying reduced-order models of grid-forming converters, with three techniques being compared: balanced truncation, singular perturbation with frequency cutoff and participation factors, and singular perturbation with energy residuals. The results show that balanced truncation achieves the highest time-domain fit, but may not provide the most reliable representation of modal properties for small-signal stability. Singular perturbation with energy residuals offers a good compromise between accuracy, physical interpretability, and modal preservation.
Decentralized control barrier function filters are designed to supplement primary frequency control and constrain frequency nadir and zenith following generation-demand imbalances in power transmission systems. These filters are implemented at each inverter, using local frequency and rate-of-change-of-frequency estimates, and are validated on the IEEE 39-bus system using a high-fidelity electromagnetic-transient model. The filters are designed to render the set of admissible frequencies forward invariant, providing bounds on the distance between state trajectories.
A stationary wavelet transform-based method is proposed for detecting and classifying DC faults in a bipolar HVDC grid, using line-mode voltage wavelet detail energy for detection and pole-voltage and DMR current-derived wavelet detail energy for classification. The method is tested using a real-time hardware-in-the-loop platform and demonstrates feasibility for real-time implementation, with fault location and traveling-wave propagation affecting transient energy and protection response time. The method distinguishes between pole-to-pole, pole-to-ground, and pole-to-DMR faults.
Decision-focused learning (DFL) is a framework for solving multistage stochastic programs, particularly in power network repair scheduling, by training a neural network on labels from offline single-scenario problems. The framework outperforms baseline policies in certain scenarios, achieving cost reductions of 14% to 23% under a binding budget, and is computationally efficient, with decision times comparable to trivial heuristics and orders of magnitude faster than model-predictive control (MPC). DFL can be applied to other multistage stochastic programs with similar structural conditions.
A compositional input-output framework for assessing stability in interconnected grid subsystems uses passivity, which introduces new grid stability challenges due to the energy transition and converter-dominated grids. A novel optimization approach is proposed to tune controller parameters to maximize passivity over specific frequency bands, addressing the current gap in practice. The method is validated on two case studies: a grid-following converter and a multi-converter microgrid.
DynaSeek, a large language model-driven framework, proposes a new method for discovering explicit hybrid differential-algebraic equations of grid-tied inverters from limited measurements. The framework integrates physics-constrained symbolic skeleton synthesis with joint numerical estimation of shared model parameters and record-specific latent initial states. DynaSeek reduces transient trajectory reconstruction errors by one to two orders of magnitude compared to existing methods, enabling reliable large-signal stability assessment of inverters.
Energy Storage & Markets 2 papers
Replacing a fixed 20% battery reserve with a county-risk threshold increases observed five-hour backup coverage from 75.0% to 86.5%, adding $10.2 in annualized margin per home. The results come from a simulation that considers market discharge and household outages, and provide a basis for designing residential battery programs that balance market value and backup service. The study's findings are based on 21 training runs and 41 county mass-outage episodes.
A hybrid solar-biogas-battery energy storage microgrid was optimized using Xendee software, resulting in an annual energy delivery of 61.3 GWh, a 2-year payback period, and a levelized cost of electricity of 0.1991 USD/kWh. The microgrid achieves 32.2% total savings versus grid-only supply while exporting 28.8 GWh annually. The project's internal rate of return (IRR) is 42.91%.
Other 2 papers
A robust optimization framework is developed for energy system capacity expansion under line outage uncertainty, allowing for the simulation of thousands of outage scenarios and hedging against the most severe ones. The framework achieves a VaR bound of less than 1% in a 25-node case study, and the robust plans are shown to nearly eliminate loss of load and have a lower mean system cost compared to a deterministic plan and a reserve-margin heuristic. The approach mainly changes the type and location of capacity, rather than adding more generation capacity.
Causal algorithmic recourse models how interventions change an individual's features to reverse unfavorable decisions, but existing methods may not account for ambiguity in causal mechanisms. Two new methods, Worst-Case Recourse and Graph-Weighted Recourse, are proposed to find low-cost actions that succeed across multiple candidate graphs or a fraction of graph weight. Relaxing robustness requirements increases the number of valid recommendations for recourse, but may lower the validity of actions.